You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
Issue: Camera is sporadically not sending onvif off events or seems like onvif on/off events are inverted.
This has the effect that alert state will be left on after motion finished and New Event will keep recording forever.
I worked around this by setting the two occurrences of Event_Poller_Closes_Event to false in zm_monitor.cpp.
Maybe there's no real solution other than a toggle option to disable this since it could be the camera that is malfunctioning.
The text was updated successfully, but these errors were encountered:
Zoneminder v1.37.48 git master 2024-01-04.
Camera: Besder (cheap-o), h265 HEVC only 20fps@1080p, chipset: XM540.
Issue: Camera is sporadically not sending
onvif off
events or seems likeonvif on/off
events are inverted.This has the effect that alert state will be left on after motion finished and New Event will keep recording forever.
I worked around this by setting the two occurrences of Event_Poller_Closes_Event to false in zm_monitor.cpp.
Maybe there's no real solution other than a toggle option to disable this since it could be the camera that is malfunctioning.
The text was updated successfully, but these errors were encountered: