Here at Kelly Generator, we strive to provide quick and professional solutions for our customer's electrical needs around the clock. #KGE #BecausePowerMatters
Kelly Generator and Equipment, Inc., and Kelly Generator & Equipment of PA & WV, Inc.’s Post
More Relevant Posts
-
Power System Engineer | Transmission Lines and Substation Professional | Project Management | Tendering Expert |
What Components/Material are used in Transmission Line Construction? #Post 6/16 In continuation of #post 5/16 5-Tower Accessories The fifth point, "Tower Accessories," encompasses various components and fittings that are essential for the proper functioning and stability of transmission towers. These accessories play crucial roles in supporting conductors, maintaining clearances, and ensuring the overall integrity of the transmission line. #electricalengineer #powersystem #substation #transmissionline #energy
To view or add a comment, sign in
-
The next shipment of equipment for one of our clients, the CMM-10 units for transformer oil processing. #transformer #electricalengineering #power #energy #electricity
To view or add a comment, sign in
-
Power System Engineer | Transmission Lines and Substation Professional | Project Management | Tendering Expert |
What Components/Material are used in Transmission Line Construction? #Post 3/16 In continuation of #post 2/16 2- Insulators Certainly! The second point, "Insulators," is a critical component in transmission line construction. Insulators are used to support and electrically isolate the conductors from the supporting structures, preventing unwanted electrical leakage and ensuring the safe and reliable operation of the transmission line. #electricalengineer #powersystem #substation #transmissionline #energy
To view or add a comment, sign in
-
Battery & Power Systems Analyst | Expert in Battery Energy Storage Systems | EV & E-Mobility Enthusiasts | Mechanical Engineer Technologist| Industrial Automation Technician
POWER LIMIT= 80% Can 30KVA Diesel Generator carry a Load of 351Amps? In an electrical system, power is the product of voltage and current. The unit of power is watts, which is equal to volts multiplied by amps. In the case of a 30 KVA generator, "KVA" stands for kilovolt-amperes, which is a measure of the apparent power that the generator can produce. To determine the amperage of a generator, we need to know the voltage and the apparent power output. For example, if the generator produces 30 KVA at a voltage of 240 V, we can use the formula: Current (in amps) = Power (in watts) / Voltage (in volts) Since 1 KVA is equal to 1,000 volt-amperes (VA), we can convert 30 KVA to watts by multiplying it by 1,000, which gives us 30,000 watts. Plugging in the values, we get: Current = 30,000 watts / 240 volts = 125 amps So, in this case, a 30 KVA generator operating at 240 V can produce up to approximately 125 amps of current. However, if the voltage is different, the amperage will vary accordingly. #dieselgenerator #generatorservices #powergeneration #powergrid #generatormaintenance #mechanicalengineering #powersystems
To view or add a comment, sign in
-
In the summer, we are facing power outages. The electricity of the factory is supplied by the diesel generator unit shown in this video. #electrical #electrical_engineering #Control_engineering #diesel_generator
To view or add a comment, sign in
-
M.tech in energy engineering|| Solar professional || Design Engineer|| 🌞solar PV technology🌞||🛰️solar system design (Autocad , solid works ,staadpro,SketchUp , PV syst, helioscope , google earth🛰️ ||
Pole mounted substation is used for the low voltage power distribution. It generally supplies the electrical power supply to domestic consumers. It steps up the voltage from three-phase three-wire 11KV into three-phase four-wire 415V and single-phase 230V power supply.
To view or add a comment, sign in
-
-
CBUC38120D100-backup fuse-Eaton Cooper Cooper Power Systems ELSP fuse is designed specifically for transformers to prevent short circuits and current overload, ensuring safe operations of transformers. These are currently use by transformer manufacturers, the 15.5KV and 38KV series. Its composition are metal fuse elements, insulation materials, and springs that are design to adapt in abnormal current situations. Advantages: > Ultra-fast protection due to current overload and protect the transformer from risks. > Reliable and low maintenance cost. Performs well and easily adapt to extreme environment conditions and has long lifespan with minimal maintenance requirement. > Variable applications. Transformers, Substations, Cable lines, and other Power Equipment > Lead time advantage: 4-6 weeks #asbeam.com#ab@asbeam.com #cooperpowersystems#ELSP fuse#CBUC38120D100#backupfuse#38KVseries
To view or add a comment, sign in
-
Station transformers are transformers in which the input is from the generator and the output goes to the bus bar. Auxiliary transformers are used for the auxiliary machines inside the plant to run the plant. Let's share your knowledge #Coalfired power plant #Transformers
To view or add a comment, sign in
-